Fitting and Filling the Coolant Supply System (see figures B1B2)
- The coolant system must only be used when drilling with the annular cutter.
- The coolant supply system must not be used when drilling into vertical or sloped surfaces, or drilling overhead. In this case, manually supply the coolant (e.g. using a spray bottle).
- Insert the coolant tank (12) onto the holder (24).
- Connect the connectors (13) to the coolant house (14) .
The coolant tank (12) must be filled with coolant before drilling.
- Close the coolant valve (25).
- Unscrew the screw cover (11) of the coolant tank and fill the coolant tank (12) with coolant.
- Screw the screw cover (11) back onto the coolant tank.
- Open the coolant valve (25) fully before switching on the power tool.